Find the index change a sound wave puts on a waveguide#
Find how much a voltage on an interdigital transducer shifts the effective index
of a waveguide that its sound wave crosses: the acousto-optic shift of a
guided mode per volt, as a complex phasor at each acoustic frequency, the
voltage-length product \(V_\pi L\) of one arm and of a push-pull pair, and the
voltage of the wave that reaches the transducer. A
gfem.Piezoelectric solve that keeps its fields gives the strain and the
electric field of the wave; gfem.acousto_optic_shift reads them on the
optical cross-section and weighs them against one mode solve, through the crystal’s
photoelastic tensor and electro-optic tensor.
The device is the section of the acousto-optic tutorial: x-cut lithium niobate film, two ribs, aluminium
fingers on an oxide and silicon stack, light at 1.55 µm. The tutorial’s
transducer_section.py and
aom_section.py mesh the acoustic section and
the optical windows with netgen; here at 2.5 times the tutorial’s edge lengths and
three frequencies, which is quicker and moves the shift by 2 %. The shift is first
order in the acoustic fields: the mode is solved once and held constant, and the shift
is the sum over the section of its weights times the change of permittivity the fields
cause.
A crystal with a photoelastic tensor#
A material’s photoelastic_tensor is the contracted \(p^E_{IJ}\), a 6 × 6 array,
dimensionless, in the frame of the material’s axes: rows and columns in the Voigt
order \(xx, yy, zz, yz, xz, xy\), with the engineering shear strain, so that
\(\Delta(\varepsilon_r^{-1})_I = p_{IJ} S_J\)
(Conventions, “Photoelastic tensor”). It belongs to the optical crystal,
beside its eps_r and its electro_optic_tensor; the acoustic model has its own
material for the same crystal, with the stiffness and the piezoelectric tensor, and the
two must share one axes, which the shift cannot check.
import dataclasses
import urllib.request
import jax
import jax.numpy as jnp
import numpy as np
import scipy.constants as sc
import gfem
base = "https://raw.githubusercontent.com/benvial/gfem/main/docs/tutorials/"
for name in ("transducer_section.py", "aom_section.py"):
urllib.request.urlretrieve(base + name, name)
from aom_section import optical_window # noqa: E402
from transducer_section import transducer_section # noqa: E402
# the acoustic crystal: stiffness (Pa) and piezoelectric tensor (C/m^2), x-cut
c11, c12, c13, c14, c33, c44 = 203e9, 53e9, 75e9, 9e9, 245e9, 60e9
c_ln = np.array(
[
[c11, c12, c13, c14, 0, 0],
[c12, c11, c13, -c14, 0, 0],
[c13, c13, c33, 0, 0, 0],
[c14, -c14, 0, c44, 0, 0],
[0, 0, 0, 0, c44, c14],
[0, 0, 0, 0, c14, (c11 - c12) / 2],
]
)
e15, e22, e31, e33 = 3.7, 2.5, 0.2, 1.3
e_ln = np.array(
[
[0, 0, 0, 0, e15, -e22],
[-e22, e22, 0, e15, 0, 0],
[e31, e31, e33, 0, 0, 0],
]
)
c_si = np.zeros((6, 6))
c_si[:3, :3] = 63.9e9
c_si += np.diag([165.7e9 - 63.9e9] * 3 + [79.6e9] * 3)
axes = ((0, 1, 0), (1, 0, 0), (0, 0, -1))
q = dict(mechanical_quality_factor=200.0)
ln = gfem.Material(
eps_r=(44.0, 44.0, 29.0), axes=axes, stiffness=c_ln,
piezoelectric_tensor=e_ln, mass_density=4700.0, **q,
) # fmt: skip
oxide = gfem.Material(
eps_r=3.9, stiffness=gfem.isotropic_stiffness(73e9, 0.17), mass_density=2203.0, **q
)
silicon = gfem.Material(stiffness=c_si, mass_density=2329.0, **q)
metal = gfem.Material(
stiffness=gfem.isotropic_stiffness(70e9, 0.35), mass_density=2700.0, **q
)
# the optical crystal: the same axes, its index, the clamped r and p^E (Weis and Gaylord)
frequency = sc.c / 1.55e-6 # Hz
p11, p12, p13, p14, p31, p33, p41, p44 = (
-0.026, 0.090, 0.133, -0.075, 0.179, 0.071, -0.151, 0.146,
) # fmt: skip
p_ln = np.array(
[
[p11, p12, p13, p14, 0, 0],
[p12, p11, p13, -p14, 0, 0],
[p31, p31, p33, 0, 0, 0],
[p41, -p41, 0, p44, 0, 0],
[0, 0, 0, 0, p44, p41],
[0, 0, 0, 0, p14, (p11 - p12) / 2],
]
)
optical_ln = dataclasses.replace(
gfem.materials.lithium_niobate(frequency=frequency, axes=axes),
photoelastic_tensor=p_ln,
)
optical_oxide = gfem.materials.silica(frequency=frequency)
The tensor is a property of the material, so a region of crystal carries it in every model it appears in. It may sit beside an
electro_optic_tensorand not beside astiffnessor apiezoelectric_tensor: a material is either the optical crystal or the acoustic one, and giving both raises.The shift treats \(p\) as the tensor at constant electric field, \(p^E\), and the electro-optic tensor as the clamped \(r^S\): the strain is counted through \(p\) and the piezoelectric field through \(r\).
gfem.materials.lithium_niobatecarries the clamped \(r^S\). A free \(r^T\) would count the strain twice.p_lnis a literature set for the bulk crystal, not the film’s: published values differ by tens of percent. The shift is linear in the tensor, so another set rescales it with no new acoustic solve.axesmust be right-handed: the tensors’ signs follow the crystal’s frame.
The shift per volt#
The acoustic section is solved once, at the frequencies of the band, with the fields
kept. Each arm has an optical window: the film, the rib, oxide below and air
above, meshed in the acoustic section’s own coordinates, so the acoustic fields are
read at the optical points with no offset. A wave port on its end face "front" carries
the mode.
section = transducer_section(edge_scale=2.5)
frame = gfem.DampingFrame(["ln_frame", "box_frame", "si_frame"])
model = gfem.Model(
section.mesh,
materials={
"ln": ln, "ln_frame": ln, "box": oxide, "box_frame": oxide,
"si": silicon, "si_frame": silicon, "signal": metal, "ground": metal,
"air": gfem.Material(),
},
excluded={"mechanical": ["air"], "em": ["si", "si_frame"]},
) # fmt: skip
sweep = gfem.Piezoelectric(
[0.85e9, 0.8625e9, 0.875e9],
terminals={"signal": "signal"},
ground="ground",
clamped="bottom",
damping_frame=frame,
keep_fields=True,
)
acoustic = gfem.solve(model, sweep)
def window(x_centre, crystal=optical_ln):
"""One arm's optical window; its mode is on the end face "front"."""
materials = {"box": optical_oxide, "slab": crystal, "rib": crystal}
return gfem.Model(
optical_window(x_centre, h_film=0.12, h_outer=0.5),
materials={**materials, "air": gfem.Material()},
ports=[gfem.WavePort("arm", "front")],
)
arms = [window(x) for x in section.arms[:, 0]]
a, b = (
gfem.acousto_optic_shift(
w, acoustic, port="arm", frequency=frequency, terminal="signal", mode=1
)
for w in arms
)
print(a)
print(
f"arm b / arm a: {abs(complex(b.delta_n_eff_per_volt[1] / a.delta_n_eff_per_volt[1])):.4f}"
)
print(f"V_pi L of arm a at 0.8625 GHz: {100 * float(a.v_pi_l[1]):.3f} V cm")
AcoustoOpticShift(port 'arm', mode 1, terminal 'signal', 1.93414e+14 Hz, n_eff 1.840038, 3 acoustic frequencies 8.5e+08 to 8.75e+08 Hz, v_pi_l 0.0774106 to 0.0942257 V m)
arm b / arm a: 0.9875
V_pi L of arm a at 0.8625 GHz: 8.496 V cm
delta_n_eff_per_voltis the complex \(\delta n\) at each acoustic frequency (acoustic_frequency), per volt onterminalwith every other terminal and the ground at 0 V. With a drive \(\mathrm{Re}(V e^{i\Omega t})\) the effective index is \(n_\mathrm{eff} + \mathrm{Re}(\delta n\,V e^{i\Omega t})\) to first order, the phasor convention of gfem’s \(e^{+i\omega t}\) (Conventions).One mode solve serves every kept frequency: the acoustic fields are only read. It gives
n_eff, the index without the wave.phase_per_length_per_voltis \(k_0\,\delta n\) in rad/(V m).v_pi_lis \(\lambda / (2|\delta n|)\) in V m of one arm at each acoustic frequency:100 * v_pi_lis in V cm.A result that kept no fields, a terminal the result does not have, and several terminals with
terminal=NoneraiseValueError; a result that kept fields for a list of frequencies gives those.mode=1is the TE mode of this window. Check the polarization of the mode you pick from its field, as in Find the phase a voltage puts on a waveguide.
The photoelastic and the electro-optic part#
The shift is the sum of two phasors: the strain through \(p\) and the field through \(r\).
photoelastic_per_volt leaves the electro-optic tensor out, and
electro_optic_per_volt the photoelastic one.
pe, eo = a.photoelastic_per_volt[1], a.electro_optic_per_volt[1]
print(f"photoelastic {complex(pe):.3e}, electro-optic {complex(eo):.3e}")
print(
f"|EO / PE| = {abs(complex(eo / pe)):.3f}, phase {np.degrees(np.angle(complex(-eo / pe))):+.1f} deg from opposed"
)
print(f"|total / PE| = {abs(complex(a.delta_n_eff_per_volt[1] / pe)):.3f}")
photoelastic -5.481e-06+1.200e-05j, electro-optic 2.592e-06-3.353e-06j
|EO / PE| = 0.321, phase +13.2 deg from opposed
|total / PE| = 0.691
On this stack the two have opposite signs and the electro-optic part is about a third
of the photoelastic one, so a model without the strain, or without the field, is wrong
by tens of percent. Both parts are counted in delta_n_eff_per_volt.
Push-pull and the incident wave#
The two ribs sit an odd number of half-wavelengths apart, so the arms’ shifts are in antiphase. Driven push-pull in a Mach-Zehnder interferometer, the phase difference is the difference of the shifts:
per volt on the fingers. That is not the voltage of the source. For an incident wave
\(V_\mathrm{inc}\) on a source impedance \(Z_0\), the fingers carry
\(V_\mathrm{IDT} = 2Z\,V_\mathrm{inc}/(Z_L + Z_0)\), with \(Z = 1/(W Y')\) the
transducer’s impedance at the aperture \(W\), from admittance_per_length, and
\(Z_L = Z + R_s\) its load with the fingers’ series resistance. The product per volt of
incident wave is the one per volt on the fingers times \(|(Z_L + Z_0)/(2Z)|\).
wavelength = sc.c / frequency
v_pi_l = (
100
* wavelength
/ (2 * np.abs(np.asarray(a.delta_n_eff_per_volt - b.delta_n_eff_per_volt)))
)
aperture, r_s, z_0 = 400e-6, 26.7, 50.0 # m, ohm (the tutorial's), ohm
z = 1 / (aperture * np.asarray(acoustic.admittance_per_length)[:, 0, 0]) # ohm
refer = np.abs((z + r_s + z_0) / (2 * z))
for f, pp, k in zip(a.acoustic_frequency, v_pi_l, refer, strict=True):
print(
f"{f / 1e9:.4f} GHz: {pp:.2f} V cm per volt on the fingers, {pp * k:.2f} V cm incident"
)
0.8500 GHz: 3.89 V cm per volt on the fingers, 2.07 V cm incident
0.8625 GHz: 4.27 V cm per volt on the fingers, 2.28 V cm incident
0.8750 GHz: 4.74 V cm per volt on the fingers, 2.52 V cm incident
Arms of length \(L\) driven with amplitude \(V\) on the fingers have a phase difference \(\pi V L / (V_\pi L)\), so \(V_\pi = V_\pi L / L\). The arms run along the fingers, so their length is the transducer’s aperture.
Where the windows sit, and the gradient#
offset=(dx, dy) in metres moves the optical section against the acoustic one: the
fields are read at the optical points plus offset. It is a move of the reading,
not of the mode, and differentiable. The shift is exactly linear in
the tensors and the acoustic fields, and jax.grad reaches the tensors (give the
crystal as a gfem.MaterialField), the offset, and every input the
piezoelectric solve differentiates (the acoustic materials and the node maps of
Differentiate a transducer’s admittance), through the kept fields. The optical model’s own nodes
are held constant: a jax.grad through them raises
gfem.errors.NonDifferentiableError, and a waveguide width needs a
remesh and a finite difference.
def push_pull(p, slide):
"""|dn_a - dn_b| per volt at 0.8625 GHz, with the windows slid by `slide` (m)."""
crystal = gfem.MaterialField(
eps_r=jnp.asarray(optical_ln.eps_r),
axes=axes,
electro_optic_tensor=optical_ln.electro_optic_tensor,
photoelastic_tensor=p,
)
dn = [
gfem.acousto_optic_shift(
window(x, crystal), acoustic, port="arm", frequency=frequency,
terminal="signal", mode=1, offset=jnp.stack([slide, 0.0 * slide]),
).delta_n_eff_per_volt[1]
for x in section.arms[:, 0]
] # fmt: skip
return jnp.abs(dn[0] - dn[1])
p0, s0 = jnp.asarray(p_ln), jnp.asarray(0.0)
value, (d_p, d_slide) = jax.value_and_grad(push_pull, argnums=(0, 1))(p0, s0)
print(f"|dn_a - dn_b| = {float(value):.4e} per V")
shares = np.asarray(p0 * d_p / value) # the change per unit relative change of p_IJ
labels = ("xx", "yy", "zz", "yz", "xz", "xy")
for k in np.argsort(-np.abs(shares), axis=None)[:3]:
i, j = divmod(int(k), 6)
print(f"p_{labels[i]},{labels[j]}: {shares[i, j]:+.3f}")
h = 1e-12 # m: no reading point crosses an element edge in this step
fd = (push_pull(p0, s0 + h) - push_pull(p0, s0 - h)) / (2 * h)
print(
f"d/dslide = {float(d_slide):.4e} per V and per m, central difference {float(fd):.4e}"
)
|dn_a - dn_b| = 1.8129e-05 per V
p_yy,yz: +1.191
p_yy,xx: +0.153
p_yy,yy: +0.105
d/dslide = -3.9568e-01 per V and per m, central difference -3.9568e-01
The step of a check. The strain is piecewise polynomial on the acoustic mesh and jumps across element edges, and the derivative is that of the reading at fixed points in their elements. A central difference in
offsetwhose step carries a reading point across an edge adds the jump and is no check of the gradient: use a step far smaller than the elements (here 1 pm for edges of 0.1 µm), and read the difference at two steps. The same holds for a node map moving the acoustic mesh under fixed points.The acoustic solve is the gradient’s cost. With the result held fixed, the gradient costs one adjoint pass over the readings and the mode solves of the forward call. Through a piezoelectric solve it adds that solve’s adjoint.
Check your results#
Antiphase. The two arms’ shifts have opposite phase, \(\arg(\delta n_b/\delta n_a) = 180°\) to a fraction of a degree, when the ribs are an odd number of half wavelengths apart: this follows from the geometry, not the frequency.
Linearity. The shifts of several terminals add, each times its drive; the shift scales with the tensors. Doubling
photoelastic_tensordoublesphotoelastic_per_volt.Convergence. The shift reads the strain’s gradient on the acoustic mesh, and the mode on the window’s. Refine
edge_scale(the tutorial’s 1.5 against this page’s 2.5 moves the shift by 2 %) and the window’sh_filmandh_outer(the tutorial’s 0.08 and 0.4 µm against this page’s 0.12 and 0.5 µm: 0.15 %).The mode. Compare
n_effwith a mode solve of the window alone (gfem.PortMode).
Limits#
Photoelastic and electro-optic terms only. The moving boundaries and the rotation of the crystal by the displacement (roto-optic) are not counted. For a wave whose displacement moves no boundary of the optical section, such as the shear wave polarized along the guide here, they vanish to first order; for Rayleigh and Lamb waves, which move the section’s boundaries, they are an approximation.
First order in the acoustic fields, with the mode held constant, for a lossless optical section: a complex
eps_r, atan_deltaor aconductivityraisesNotImplementedError, and so does a 2D optical model and a sequence of optical frequencies.The strain and the field are read at the quadrature points of each tetrahedron behind the section’s triangles. A point outside the acoustic mechanical domain, for an element with a
photoelastic_tensor, or outside the potential’s support, for one with anelectro_optic_tensor, raisesValueErrorand names it.An optical element with neither tensor adds nothing, and a model with none raises.
A cross-section: the arms’ length is the aperture and the shift uniform along it.
Next#
An acousto-optic modulator: light phase-modulated by a shear plate wave: the push-pull modulator, the shift over a band, the derivative in the pitch and the position of the arms.
Find a transducer’s admittance and reflection: the admittance, the damping frames and the strain.
Find the phase a voltage puts on a waveguide: the static-field counterpart, with a potential as the drive.
Differentiate a transducer’s admittance: the gradients through the acoustic solve.