See S in the time domain: TDR, TDT and impedance profiles#
What would a time-domain reflectometer show on your device: the reflected step at a port (TDR), the impedance along the line behind it, the transmitted step (TDT) and the impulse response? gfem reads them from S on a harmonic grid by an inverse Fourier transform, as a network analyzer’s time-domain mode does, with no time-domain solve. Each is a time response: a dimensionless wave ratio over time. Phases follow \(e^{+i\omega t}\), so positive time is later (Conventions, “Time responses”). The device is the line of Solve a device: S-parameters, modes and capacitance: 10 mm of air line, 20 mm of \(\varepsilon_r = 10\) ceramic, 10 mm of air line.
A step and an impedance profile#
Solve on the harmonic grid \(f_k = k\,\Delta f\), \(k = 1, \dots, N\): the record lasts \(1/\Delta f\) and the top frequency sets how sharp the edges are.
import math
import urllib.request
import numpy as np
import gfem
url = "https://raw.githubusercontent.com/benvial/gfem/main/docs/tutorials/data/line.msh"
urllib.request.urlretrieve(url, "line.msh")
mesh = gfem.Mesh.from_gmsh("line.msh", length_unit="mm")
z_line = 376.73 / 6 # ohm: the 6 mm wide, 1 mm high parallel-plate line in air
plates = [gfem.PEC("bottom"), gfem.PEC("top")]
ports = [
gfem.LumpedPort("p1", "port1", "+z", impedance=z_line),
gfem.LumpedPort("p2", "port2", "+z", impedance=z_line),
]
ceramic = {"feed": gfem.Material(), "design": gfem.Material(eps_r=10.0)}
model = gfem.Model(mesh, materials=ceramic, boundaries=plates, ports=ports)
duration = 20e-9 # s: the record, 1 / df
f_max = 20e9 # Hz: the top of the grid
df = 1 / duration
n = math.ceil(f_max / df)
freqs = df * np.arange(1, n + 1) # harmonic grid: k df, k = 1..n
result = gfem.solve(model, gfem.Driven(frequency=freqs, sweep="adaptive"))
s = result.s
step = s.step_response() # TimeResponse, Kaiser window beta = 6
z = step.impedance("p1") # impedance profile seen from port 1, ohm
ceramic_z, late_z = np.interp([0.28e-9, 9e-9], step.time, z)
print(f"on the ceramic {ceramic_z:.2f} ohm, late {late_z:.2f} ohm")
print(f"by hand {z_line / np.sqrt(10):.2f} ohm and {z_line:.2f} ohm")
print(len(result.sweep.sampled_frequencies), "full solves")
on the ceramic 19.86 ohm, late 62.78 ohm
by hand 19.86 ohm and 62.79 ohm
11 full solves
step.values[m, i, j]is the wave leaving portports[i]at timestep.time[m]for a unit step of incident wave at portexcited[j], every other port ending on its reference impedance.step["p1", "p1"]is the reflected step \(\rho(t)\) (TDR).The impedance profile is \(Z(t) = Z_0 \frac{1 + \rho(t)}{1 - \rho(t)}\), with \(Z_0\) the port’s real reference impedance,
s.z_ref: 62.79 Ω here. The ceramic reads \(Z_0/\sqrt{10}\) from the round trip to its front face, \(2 \times 10\ \mathrm{mm}/c = 66.7\) ps, to the round trip to its back face, 489 ps; after that the far air line, ended on port 2’s 62.79 Ω.step.timeis the whole two-sided record, \(-T/2\) to \(T/2\) with \(T = 1/\Delta f\), negative times included: the window’s pre-response lives there. Slice it for a plot.The adaptive sweep solves 11 of the 400 frequencies in full (Sweep many frequencies): a dense grid costs few solves.
step.to_xarray()labels the responses by time and port name (thexarrayextra).
Choose the grid#
Record. The record \(1/\Delta f\) must outlast the response: make it at least 5 times the time the device takes to settle. The DC value comes from the first three frequencies, and it is exact only when \(\Delta f\) is small next to the response. On this line, whose ceramic rings for about 3 ns, a 5 ns record left a 4 % error at DC, and every step and impedance after it carries that error. Anything later than \(1/\Delta f\) aliases into the record.
Resolution. The span and the window set the 10-90 % rise of an edge, not the number of time samples:
kaiser_betaRise time, about
Edges
0 (no window)
\(0.45/f_\mathrm{max}\)
sharpest, with ringing (13 dB sidelobes)
6 (default)
\(0.99/f_\mathrm{max}\)
the usual compromise
13
\(1.44/f_\mathrm{max}\)
smoothest
n_time=only interpolates between samples; the default already gives \(\Delta t \le 1/(20 f_\mathrm{max})\).First frequency. Lumped ports solved through the tree-cotree gauge (
SolverOptions.gauge, on by default for a direct solve on one CPU process) can start at \(\Delta f\), however low. Wave ports, and solves without the gauge, lose digits below the mesh’s low-frequency floor: choose \(\Delta f\) at or above the floorgfem.LowFrequencyWarningnames.Long lines. An adaptive sweep of a line \(W\) phase wraps long at \(f_\mathrm{max}\) needs about \(W + 10\) samples. Above 10 wraps, raise
gfem.SolverOptions(adaptive_max_samples=...)from its default of 20, or the sweep stops withgfem.SweepNotConvergedWarningand gives unusable S.
The transmitted step and the rise time#
step["p2", "p1"] is the TDT: the wave reaching port 2 for a unit step sent
into port 1. gfem.rise_time reads the 10-90 % time of one edge;
give it a slice around that edge.
tdt = np.asarray(step["p2", "p1"])
print(f"the TDT settles at {tdt[-1]:.4f}") # S21 at DC
edge = (step.time > 0) & (step.time < 0.3e-9) # the first reflection only
rise = gfem.rise_time(step.time[edge], np.asarray(step["p1", "p1"])[edge])
print(f"rise {rise * 1e12:.1f} ps, 0.99 / f_max = {0.99 / f_max * 1e12:.1f} ps")
the TDT settles at 1.0000
rise 49.2 ps, 0.99 / f_max = 49.5 ps
The TDT is a ratio of power waves. On ports with different reference impedances the voltage ratio is \(S_{21}\sqrt{Z_{0,2}/Z_{0,1}}\); here both are 62.79 Ω and the two agree.
rise_timenormalizes to the slice’s first and last samples. On the whole TDT of this line, whose ceramic sends back echoes, it gives a meaningless number: always slice around one edge.
The impulse response#
s.impulse_response() is the derivative of the step, scaled so that an
isolated reflection \(\Gamma\) peaks at \(\Gamma\). The front face of the
ceramic reflects \(\Gamma = (Z_0/\sqrt{10} - Z_0)/(Z_0/\sqrt{10} + Z_0)\):
impulse = s.impulse_response()
h = np.asarray(impulse["p1", "p1"])
i = int(np.argmin(h))
print(f"peak {h[i]:.3f} at {impulse.time[i] * 1e12:.1f} ps")
gamma = (1 / np.sqrt(10) - 1) / (1 / np.sqrt(10) + 1)
print(f"by hand {gamma:.3f} at {2 * 10e-3 / 299792458.0 * 1e12:.1f} ps")
peak -0.519 at 65.9 ps
by hand -0.519 at 66.7 ps
The impulse is dimensionless, like the step, and the step ends at \(S(0)\).
scikit-rf’s
Network.impulse_responseuses a Hamming window and does not normalize the peak: its steps agree with gfem’s, its impulse heights do not.
Data with the other sign of time#
gfem’s S follows \(e^{+i\omega t}\), and the inverse transform has no
conjugation, so a delay is a positive time. Data from a code that writes
\(e^{-i\omega t}\), or from a file written by one, are the complex conjugate:
conjugate them before building a gfem.NetworkParameters, or every
reflection lands at a negative time, mirrored about zero.
Guides with a cutoff#
A wave port on a waveguide has no S below its cutoff, so no harmonic grid
reaches down to DC. s.impulse_response(mode="band_pass") takes any evenly
spaced grid across the band, applies a full Kaiser window and returns the
magnitude \(|h(t)|\): where along the guide each reflection comes from, without
its sign. There is no band-pass step: a step needs DC.
S not on a harmonic grid#
A log grid, or one that starts well above \(\Delta f\), raises ValueError
whose message gives the grid to solve on. To use such S anyway, resample it
through a rational model, explicitly:
s.fit_rational().network(df * np.arange(0, n + 1)).step_response()
(Export S as a SPICE or Verilog-A model). The fit has its own tolerance, passivity and
warnings, and no gradient, which is why gfem never does it for you.
Under jax.grad#
The time views are written in jax.numpy: an objective on \(Z(t)\) or on a
TDT differentiates with respect to the design through S, with no extra step
(Differentiate an adaptive frequency sweep for a differentiable adaptive sweep). When the
reference impedance is traced too (a wave port’s \(Z_{PV}\) moves with the
design), pass z0=: inside jax.grad or jax.jit gfem cannot check that
z_ref is one real value per port, so it asks for the reference to use.
Check your results#
The late impedance is the far end’s load. Read \(Z(t)\) near the end of the record: it should be the load behind the last discontinuity, port 2’s 62.79 Ω here.
The transmitted step ends at \(S_{21}(0)\). 1 for this lossless line.
A longer record changes nothing. Halve \(\Delta f\) and compare the plateaus. A change means the record was too short.
How gfem itself is checked: How gfem is checked.
Limits#
No gating and no peeling: the impedance profile is exact up to the first round trip past the first discontinuity. After that, multiple reflections mix in: a 30 Ω load behind a 75 Ω line, seen from a 50 Ω port, reads 32.55 Ω.
Anything later than \(1/\Delta f\) aliases into the record.
DC comes from an extrapolation of the first three frequencies, unless S has a 0 Hz point; it needs a long enough record.
impedanceneeds a step, an excited port and a real reference impedance: a wave port without avoltage_pathhas none: give it one.
Next#
Export S as a SPICE or Verilog-A model: the same S as a SPICE subcircuit or a Verilog-A module, and its exact step.
Sweep many frequencies: the adaptive sweep behind the dense grid.
gfem.TimeResponseandgfem.NetworkParametersin the API reference.