Find a transducer’s admittance and reflection#

Find the admittance of electrodes on a piezoelectric crystal, such as an interdigital transducer, per metre of aperture, over a band of frequencies: the current into a terminal per volt, the capacitance of the electrodes with the crystal held still, the displacement the voltage launches, and the reflection of the finished device on a circuit. gfem.Piezoelectric solves a 2D section of piezoelectric, elastic and dielectric regions, with the fields held uniform along \(z\), so a finger pattern is one cross-section.

The device is the transducer of the tutorial: aluminium fingers at a 2.2 µm pitch on a 360 nm film of x-cut lithium niobate over oxide and a silicon handle. The tutorial’s transducer_section.py meshes it with netgen; here with four fingers at twice the tutorial’s edge lengths, which takes a few seconds a frequency.

A crystal with a stiffness and a piezoelectric tensor#

A material’s stiffness is the stiffness \(c^E\), a 6 × 6 matrix in Pa, and its piezoelectric_tensor the piezoelectric tensor \(e\), a 3 × 6 matrix in C/m², both in Voigt order \(xx, yy, zz, yz, xz, xy\) with engineering strain’s shear. They are the constants of \(T = c^E S - e^\mathsf{T} E\) and \(D = e S + \varepsilon^S E\): the stiffness at constant field, \(c^E\) and not \(c^D\), and the stress constants \(e\), not the strain constants \(d\). The eps_r is the clamped permittivity \(\varepsilon^S / \varepsilon_0\). All three are in the frame of the material’s axes, whose rows are the crystal’s \(x\), \(y\) and \(z\) in the section’s coordinates (a right-handed set), as for the electro-optic tensor (Conventions, “Piezoelectric problems”). The mechanical quality factor mechanical_quality_factor \(Q_m\) lumps the solid’s loss.

An isotropic solid takes gfem.isotropic_stiffness from its Young’s modulus and Poisson’s ratio. A cubic one is a 6 × 6 you write from \(c_{11}\), \(c_{12}\) and \(c_{44}\).

import urllib.request

import numpy as np

import gfem

url = "https://raw.githubusercontent.com/benvial/gfem/main/docs/tutorials/transducer_section.py"
urllib.request.urlretrieve(url, "transducer_section.py")
from transducer_section import transducer_section  # noqa: E402

c11, c12, c13, c14, c33, c44 = 203e9, 53e9, 75e9, 9e9, 245e9, 60e9
c_ln = np.array(
    [
        [c11, c12, c13, c14, 0, 0],
        [c12, c11, c13, -c14, 0, 0],
        [c13, c13, c33, 0, 0, 0],
        [c14, -c14, 0, c44, 0, 0],
        [0, 0, 0, 0, c44, c14],
        [0, 0, 0, 0, c14, (c11 - c12) / 2],
    ]
)
e15, e22, e31, e33 = 3.7, 2.5, 0.2, 1.3  # C/m^2
e_ln = np.array(
    [
        [0, 0, 0, 0, e15, -e22],
        [-e22, e22, 0, e15, 0, 0],
        [e31, e31, e33, 0, 0, 0],
    ]
)
c_si = np.zeros((6, 6))  # cubic: c11, c12, c44
c_si[:3, :3] = 63.9e9
c_si += np.diag([165.7e9 - 63.9e9] * 3 + [79.6e9] * 3)

# x-cut: crystal y along the section's x (the wave), crystal x up, crystal z along the fingers, reversed
axes = ((0, 1, 0), (1, 0, 0), (0, 0, -1))
q = dict(mechanical_quality_factor=200.0)
ln = gfem.Material(
    eps_r=(44.0, 44.0, 29.0),
    axes=axes,
    stiffness=c_ln,
    piezoelectric_tensor=e_ln,
    mass_density=4700.0,
    **q,
)
oxide = gfem.Material(
    eps_r=3.9, stiffness=gfem.isotropic_stiffness(73e9, 0.17), mass_density=2203.0, **q
)
silicon = gfem.Material(stiffness=c_si, mass_density=2329.0, **q)
aluminium = gfem.Material(
    stiffness=gfem.isotropic_stiffness(70e9, 0.35), mass_density=2700.0, **q
)
print(c_si[0, :3] / 1e9)
[165.7  63.9  63.9]
  • axes must be right-handed: the tensors’ signs follow the crystal’s frame, and a left-handed set flips the coupling without an error.

  • A material with a stiffness but no piezoelectric_tensor is an elastic solid; one with a piezoelectric_tensor needs a stiffness. Every region of the mechanical domain (next section) needs a stiffness and a density, or gfem.solve raises gfem.MissingMaterialPropertyError and names the region.

  • The loss is the stiffness times \(1 + i/Q_m\) under \(e^{+i\omega t}\): the sign of the imaginary part is the opposite of the permittivity’s (Conventions).

Two domains: the mechanical and the electrical#

The displacement lives on the mechanical domain: every region not listed in excluded["mechanical"]. The potential lives on the electromagnetic domain: every region not listed in excluded["em"]. Air has no mechanics, so it is left out of the first. A silicon handle that is a thick, lossy, slightly conducting substrate is left out of the second, so it carries no potential. Three models of the handle are possible:

  • No potential in it (excluded={"em": ["si"]}), as here: the handle is an elastic solid. This is the lightest, and the tutorial’s choice.

  • A dielectric (leave it in the electromagnetic domain with an eps_r): the potential spreads into it. The admittance of the tutorial’s transducer moves by 2.3 %.

  • Grounded (name it in ground=): a metal plane. Use it for a conducting handle.

section = transducer_section(outer=2, between=3, edge_scale=2.0)
model = gfem.Model(
    section.mesh,
    materials={
        "ln": ln, "ln_frame": ln, "box": oxide, "box_frame": oxide,
        "si": silicon, "si_frame": silicon,
        "signal": aluminium, "ground": aluminium, "air": gfem.Material(),
    },
    excluded={"mechanical": ["air"], "em": ["si", "si_frame"]},
)  # fmt: skip
print(section.fingers, len(section.mesh.nodes))
(3, 2) 4267

Electrodes: meshed fingers or lines#

A terminal names a region of the mesh, an area or a line:

  • A meshed electrode is an area of metal: it carries displacement, stiffness and mass, with the potential fixed on the whole region. The fingers above are areas. They load the crystal, so they shift and reflect the wave.

  • A line electrode is a line on the crystal’s surface with the potential fixed on it and no mass. It is light, and it is what the closed forms assume.

A line electrode loses the mass loading, and with it the strength of the reflection: a grating’s stop band is 1.97 % wide with meshed 50 nm aluminium and 0.57 % with lines. Mesh real fingers whenever a transducer’s reflection or its resonance frequency matters, and use lines to check a closed form or to keep a model light.

A meshed electrode must stay in the electromagnetic domain: the potential is fixed on it. A line that is not named as a terminal or as ground is a free surface; a gfem.PEC line that is not a terminal is grounded.

Clamped lines and absorbing edges#

Every edge of the mechanical domain is traction-free (the displacement is free) unless named in clamped=, a list of lines where \(u = 0\), each a clamped surface. The handle’s base is the one clamped line of this section.

Waves that leave the section must not come back. A gfem.Absorbing line on a solid’s edge raises, because it is an electromagnetic boundary. The gfem.DampingFrame names the regions that absorb them instead, each a damping frame with a loss factor: there the stiffness becomes \(c (1 + i(1/Q_m + \eta r^2))\) with \(r\) the normalised depth into the frame, so the wave decays and nothing returns. Give the helper’s frames a region for each layer on each side, each region keeping its layer’s material in materials= ("ln_frame" holds the same lithium niobate as "ln"), and meshed as rectangles around the interior, every region on one side ending on one straight line.

The thickness rule, for a plane wave at normal incidence on a frame of thickness \(L\) in a medium of wavelength \(\lambda\): it reflects \(|R| \approx e^{-2\pi\eta (L/\lambda)/3}\), down to a floor of about \(3.4 \times 10^{-3}\,\eta\,(\lambda/L)^2\). A larger loss factor \(\eta\) lowers the decay term and raises the floor. The default \(\eta = 1.2\) is the best choice from four wavelengths of frame, where \(|R| < 10^{-3}\); a frame of three wavelengths takes \(\eta = 2\). The helper’s frames are 17.6 µm wide: four wavelengths of the shear plate wave. A frame much thinner than that reflects.

The result#

gfem.solve returns a gfem.PiezoelectricResult. Its admittance_per_length is the admittance per length \(Y'_{ij}(f)\) in S/m, with the shape (frequencies, terminals, terminals): the current into terminal \(i\) per volt on terminal \(j\), per metre along \(z\). The first index of the matrix is the response, the second the excitation, as in S-parameters. clamped_capacitance_per_length is the clamped capacitance, in F/m: the capacitance of the electrodes with \(\varepsilon^S\) and no displacement, which is not the low-frequency limit of \(Y'/i\omega\) (the free capacitance is larger by \(1 + K^2\)). A device of aperture \(W\) has \(Y = W Y'\).

frame = gfem.DampingFrame(["ln_frame", "box_frame", "si_frame"])  # loss factor 1.2
problem = gfem.Piezoelectric(
    np.linspace(0.84e9, 0.88e9, 3),
    terminals={"signal": "signal"},
    ground="ground",
    clamped="bottom",
    damping_frame=frame,
    keep_fields=True,
)
res = gfem.solve(model, problem)
y = np.asarray(res.admittance_per_length)  # (frequencies, terminals, terminals), S/m
print(res)
print(y.shape, bool((y[:, 0, 0].real > 0).all()))
PiezoelectricResult(terminals=['signal'], 3 frequencies 840-880 MHz, clamped capacitance per length in pF/m:
  signal:      225.2)
(3, 1, 1) True

The real part of the diagonal, the radiation conductance when the waves leave through the frames, is the power the terminal takes, so it is positive; the matrix is symmetric (reciprocal) with a positive semidefinite real part. With several terminals, terminals={"a": "signal_a", "b": "signal_b"} gives one row and column each, in that order; res.index("b") finds one.

res.to_xarray() returns the admittance and the capacitance as an xarray.Dataset labelled by frequency and terminal (the xarray extra).

Network parameters#

A circuit sees the device through its aperture and the resistance of its fingers. gfem.PiezoelectricResult.network_parameters() takes the aperture, a series resistance \(R_s\) in each terminal’s lead (one value or one per terminal) and a reference impedance, and returns the scattering parameters. The admittance of the aperture is \(Y = W Y'\); the resistance gives \(Y_t = Y (I + R Y)^{-1}\), which needs no inverse of \(Y\), and the scattering matrix is that of \(Y_t\) on the reference impedance (pseudo-waves, Conventions). For one terminal on 50 Ω, \(S_{11} = (Z_L - Z_0) / (Z_L + Z_0)\) with \(Z_L = 1/Y + R_s\).

The series resistance does not change the field solve, so it is an argument here and not of the problem. How it depends on the aperture is yours: for fingers fed from one end, \(R_s = \tfrac{R_f}{3} (1/N_S + 1/N_G)\) with the finger’s resistance \(R_f = \rho W / (w t)\).

aperture = 400e-6  # m
net = res.network_parameters(aperture, series_resistance=26.7)
print(np.round(np.asarray(net.db("signal", "signal")), 3))
net.to_touchstone("transducer.s1p")
[-0.061 -0.062 -0.065]

net.db("signal", "signal") is \(|S_{11}|\) in dB per frequency. to_touchstone writes the Touchstone file a circuit simulator reads. The function is written in jax.numpy, so it differentiates in the aperture, the resistance and the reference impedance; with several terminals it forms \(Y (I + R Y)^{-1}\) for the whole matrix.

Fields and strain#

keep_fields=True keeps the displacement and potential at every frequency and terminal (a list of frequencies keeps those). Each kept frequency and terminal holds four complex fields: mind the memory on a long sweep. res.displacement(f) is a map with the scalar fields "x", "y" and "z", in m per volt on the terminal; res.potential(f) is the potential in V per volt. They read like any field: .at(points) takes \((x, y)\) points in metres.

gfem.strain() reads the engineering strain of a displacement at points, in Voigt order \(xx, yy, zz, yz, xz, xy\), per volt. The shear wave of the section is polarized along \(z\) and carries \(S_{xz} = \partial_x u_z\), the fifth entry:

f = float(res.frequency[1])
s = np.asarray(gfem.strain(res.displacement(f), section.arms))  # (arms, 6), 1/V
print(s.shape)
print(f"|S_xz| at the two arms: {abs(s[0, 4]):.3e} and {abs(s[1, 4]):.3e} per volt")
print(
    f"potential in the air above: {abs(complex(res.potential(f).at([3e-5, 0.1e-6]))):.3f} V per volt"
)
(2, 6)
|S_xz| at the two arms: 1.077e-05 and 1.077e-05 per volt
potential in the air above: 0.834 V per volt

What raises#

  • A tetrahedral or a slab mesh: the problem is 2D (Mesh.from_gmsh of a file of triangles).

  • linear_solver="petsc" or frequency_workers above 1, and any solve under comm: one process and the sparse direct solver.

  • A gfem.Absorbing line on a solid’s edge: use a damping frame.

  • An area terminal outside the electromagnetic domain, and a region of the mechanical domain without a stiffness or a density.

  • A frame region name that is not in the mesh, or a frame with a loss factor traced by JAX.

Next#