Watch a solve run#
See what gfem does while it solves: which solver each frequency got, whether
a factorization was reused, how long each phase took, and how far a long
sweep has gone. gfem reports all of it as standard logging records on
loggers under gfem and prints nothing by default. One call turns on the
log display: one line per record on stderr, and a progress row
for each long loop while it runs.
The display is optional and changes no result: S, fields and gradients are
the same with it on or off. It colours its lines with rich, which the log
extra installs:
pip install "gfem[log]"
Without rich it prints the same lines in plain text, with ANSI colours on a terminal.
Turn it on#
Solve the line of Get started at three frequencies with the display on:
import urllib.request
import gfem
url = "https://raw.githubusercontent.com/benvial/gfem/main/docs/tutorials/data/line.msh"
urllib.request.urlretrieve(url, "line.msh")
mesh = gfem.Mesh.from_gmsh("line.msh", length_unit="mm")
z_line = 376.73 / 6 # ohm: the 6 mm wide, 1 mm high parallel-plate line in air
plates = [gfem.PEC("bottom"), gfem.PEC("top")]
ports = [
gfem.LumpedPort("p1", "port1", "+z", impedance=z_line),
gfem.LumpedPort("p2", "port2", "+z", impedance=z_line),
]
ceramic = {"feed": gfem.Material(), "design": gfem.Material(eps_r=10.0)}
model = gfem.Model(mesh, materials=ceramic, boundaries=plates, ports=ports)
gfem.log.enable()
result = gfem.solve(model, gfem.Driven(frequency=(2e9, 5e9, 8e9), excite="p1"))
14:02:29.512 INFO solver linear_solver='auto' chose 'direct' for this driven problem: 24,074 unknowns, est. 1.1 GiB factorization <= 8.0 GiB budget (half of 16 GiB)
14:02:29.512 INFO solver Driven: tree-cotree gauge on
14:02:29.936 INFO solver Tree-cotree gauge basis: 14130 -> 14130 free unknowns, 2 conductors (1 floating), template 390852 entries (ungauged 362628), basis 0.024 s, template 0.312 s
14:02:30.744 INFO solver driven forward solve at 2 GHz: direct factorized (first), iterations []
14:02:31.082 INFO solver driven forward solve at 5 GHz: direct refactorized (first), iterations []
14:02:31.220 INFO solver driven forward solve at 8 GHz: direct refactorized (other frequency), iterations []
The lines go to stderr, so they never mix with what your script prints on stdout.
gfem.log.enable("DEBUG")shows more,gfem.log.enable("WARNING")only warnings and errors. The level is a name in any case, or an int such aslogging.DEBUG.Calling
enableagain replaces the earlier settings; it never adds a second display.A job run from the command line takes the same switch:
python -m gfem run job.json --out result --log info.
Read a log line#
Each line holds, in order:
the wall-clock time the record was made, to the millisecond;
the level:
DEBUG,INFO,WARN,ERRORorCRIT;the logger’s short name:
solverfor"gfem.solver",timingfor"gfem.timing",cachefor"gfem.solve_cache",mpi,mesh,mesh_refinement;under MPI, the rank tag
rN/M(Under MPI);the record’s message, as gfem wrote it.
A solver line of a driven solve names the frequency, the direction
(forward, or backward for the adjoint solve of a gradient), the
linear solver and what it did, with the reason in brackets:
factorized: a new factorization or preconditioner, here for the first frequency;refactorized: the matrix changed (another frequency, another design), so the solver factorized again;reused: the factorization or preconditioner of an earlier solve served again, as in a design loop (Differentiate S-parameters and driven fields).
iterations lists the Krylov iterations per excited port; it is empty for a
direct solve. On a colour terminal the solver and its action stand out:
factorized and refactorized in magenta, reused in green.
How long each phase took#
timing=True adds one timing line per phase of each solve, whatever level
you asked for:
gfem.log.enable(timing=True)
again = gfem.solve(model, gfem.Driven(frequency=5e9, excite="p1"))
14:02:32.295 INFO solver linear_solver='auto' chose 'direct' for this driven problem: 24,074 unknowns, est. 1.1 GiB factorization <= 8.0 GiB budget (half of 16 GiB)
14:02:32.297 INFO solver Driven: tree-cotree gauge on
14:02:32.462 INFO timing driven discretize: 0.159 s
14:02:33.370 INFO timing driven assemble at 5 GHz: 0.871 s
14:02:33.832 INFO timing driven setup at 5 GHz: 0.469 s
14:02:33.852 INFO timing driven solve at 5 GHz: 0.0196 s
14:02:33.853 INFO solver driven forward solve at 5 GHz: direct factorized (first), iterations []
gfem.log.enable("WARNING", timing=True) shows the phases and the warnings
only. To add the seconds up per phase rather than read them line by line,
attach a handler of your own, as in Solve a device: S-parameters, modes and capacitance (“Time each phase”).
Progress rows#
While a long loop runs, the display draws one progress row for it
below the log lines: its name, a bar, the units done out of the total
(k/? when the total is not known in advance), the phase it is in
(assemble, setup, solve), the latest values of the loop (the frequency
in GHz, the iterations, the error estimate) and the elapsed time. The rows are:
Row |
One unit is |
Total |
|---|---|---|
|
one frequency of a |
the frequencies |
|
one frequency of the adjoint solves of a gradient |
the frequencies |
|
one sample frequency |
unknown |
|
the frequencies settled so far |
the output frequencies |
|
a seed solve or a mode refined |
unknown |
|
one refinement cycle |
unknown |
A phase that runs outside these loops (assembling a single solve, say) gets a spinner row of its own with its elapsed time.
A loop inside another gets its own row under its parent’s. A fixed-angle sweep’s one-frequency solves advance its one
uniform sweeprow.With frequency workers, each frequency a worker finishes advances the one row of your process.
A row disappears when its loop ends, also when it stops on an error: only the log lines stay.
Rows are drawn only where they can be erased and redrawn: in a terminal, and
in Jupyter when ipywidgets is installed (there each finished loop leaves an
empty output line). In a pipe, a file or a batch job’s output file you get
the log lines and no rows; nothing is printed in their place. On any process
but rank 0 of an MPI job there are no rows either.
Under MPI#
Launched on several ranks, the display shows rank 0’s lines only, each
tagged with the rank and the number of ranks, r0/4. Warnings and errors
show from every rank, since a rank-local warning is often the one that
matters. To read every rank’s lines, tagged r0/4 to r3/4:
gfem.log.enable(rank0_only=False)
gfem reads the rank from the launcher’s environment, so enable works before
anything imports mpi4py. Run a distributed solve covers the launch itself.
With your own handlers#
The records and their extra attributes (frequency, solver, action,
phase, seconds, …) are the same with the display on or off: a handler of
your own on a gfem logger reads them either way, and you may skip enable
altogether. While the display is on, the gfem logger stops propagating, so
a root handler (logging.basicConfig) does not print gfem’s records a second
time.
If you keep a stream handler of your own that writes to the same terminal, its lines tear through the rows; turn the rows off:
gfem.log.enable(progress=False)
rich=False gives the plain-text lines even where rich is installed, and
rich=True raises ImportError where it is not. Colour follows the usual
switches: NO_COLOR turns it off, FORCE_COLOR on.
Turn it off#
gfem.log.disable()
disable removes the display and gives the gfem logger back the level and
propagation it had before the first enable, so a level you set on gfem
while the display was on is overwritten. With the display off, disable
does nothing.
Limits#
With frequency workers, the workers’ log lines arrive together when the sweep ends; their row advances as they go.
Rows are never written to a file. A batch job’s output file holds the log lines only.
The thermal transient’s time loop has no row.
In Jupyter without rich, the plain-text lines are not coloured: a kernel’s stderr is not a terminal.
Next#
gfem.log.enable,gfem.log.disable: every argument.Solve a device: S-parameters, modes and capacitance: the phase records and their fields.
Differentiate S-parameters and driven fields: what a design loop reuses between designs.
Run a distributed solve: running on several ranks.
Save and export results: the command line
python -m gfem run.