Follow a temperature over time#
Find how fast a device heats up and cools down when its heater switches on
and off: the temperature and the phase over time, the rise time and the time
constant. gfem.TransientThermal steps the heat equation
\(\rho c_p\, \partial T/\partial t - \nabla\cdot(k \nabla T) = s(t)\, q\) on a uniform time grid, and records
traces of the temperature at every step.
The device is the heater section of Heat a device with a current and read its temperature: a TiN strip
over a silicon waveguide in oxide, on a substrate whose bottom is held at
300 K. Every material now needs its mass_density (kg/m³) and
specific_heat (J/kg/K) besides its thermal conductivity. Heat conduction is
linear, and the heat sources switch between constant levels. Time is in
seconds and temperatures in kelvin; on a cross-section, powers are per metre
of guide (Conventions, “Temperature and thermo-optic phase”).
A step on and off#
The heater dissipates 70 W per metre of guide, about the power that turns the core’s phase by \(\pi\) (Find the phase a heater puts on a waveguide). It switches on at \(t = 0\) and off at 80 µs; the run lasts 160 µs, in 320 steps of 0.5 µs. Three traces follow it: the mean temperature of the core, the temperature at the heater’s centre, and the core’s thermo-optic phase per metre.
import urllib.request
import warnings
import numpy as np
import gfem
url = "https://raw.githubusercontent.com/benvial/gfem/main/docs/tutorials/data/heater_w2.msh"
urllib.request.urlretrieve(url, "heater_w2.msh")
section = gfem.Mesh.from_gmsh_cross_section("heater_w2.msh", length_unit="um")
oxide = gfem.Material(
eps_r=1.444**2,
thermal_conductivity=1.38, # W/m/K
mass_density=2203.0, # kg/m^3
specific_heat=709.0, # J/kg/K
thermo_optic_coefficient=1e-5, # 1/K
)
silicon = gfem.Material(
eps_r=3.4777**2,
thermal_conductivity=90.0,
mass_density=2330.0,
specific_heat=711.0,
thermo_optic_coefficient=1.86e-4,
)
materials = {
"substrate": gfem.Material(
thermal_conductivity=148.0, mass_density=2330.0, specific_heat=711.0
),
"box": oxide,
"cladding": oxide,
"window": oxide,
"neighbour_window": oxide,
"core": silicon,
"neighbour": silicon,
"heater": gfem.Material(
thermal_conductivity=28.0, mass_density=5240.0, specific_heat=598.0
),
}
thermal_only = ["substrate", "box", "cladding", "heater"] # no optics there
model = gfem.Model(
section,
materials=materials,
boundaries=[
gfem.FixedTemperature("bottom", temperature=300.0),
gfem.Convection("top", coefficient=10.0, ambient=300.0),
],
ports=[gfem.WavePort("core", "front")],
excluded={"em": [*thermal_only, "neighbour", "neighbour_window"]},
)
frequency = 299_792_458.0 / 1.55e-6 # Hz
phase = gfem.thermo_optic_shift(model, None, port="core", frequency=frequency).trace()
t_off = 80e-6 # s
step = gfem.TransientThermal(
gfem.HeatSource.uniform("heater", power_per_length=70.0), # W/m
duration=160e-6, # s
steps=320,
waveform=[(0.0, 1.0), (t_off, 0.0)], # (start time in s, scale)
traces={
"core": gfem.Trace.mean("core"),
"heater": gfem.Trace.point((0.0, 2.29e-6, section.section_thickness / 2)),
"phase": phase,
"sink": gfem.Trace.heat_out_per_length("bottom"),
},
keep_fields=[40e-6],
)
run = gfem.solve(model, step)
t = np.asarray(run.time)
core = np.asarray(run.traces["core"]) # K, the core's mean temperature
on = t <= t_off
print(t.shape, run.switch_times)
print(f"core at switch-off: {core[on][-1]:.3f} K, at the end: {core[-1]:.4f} K")
heater = np.asarray(run.traces["heater"]) # K
print(f"heater centre at switch-off: {heater[on][-1]:.2f} K")
phase_320 = np.asarray(run.traces["phase"]) * 320e-6 # rad, over 320 um of guide
print(f"phase at switch-off: {phase_320[on][-1]:.4f} rad")
(321,) (0.0, 8e-05)
core at switch-off: 311.978 K, at the end: 300.0038 K
heater centre at switch-off: 331.80 K
phase at switch-off: 3.1203 rad
run.timeis the time grid,steps + 1times from 0 toduration, and each trace has one value per time. A switch time must be on the grid; one off it raises, naming the nearest grid times.The waveform scales every heat source of the problem: off before its first start time, then each scale until the next start time.
gfem.Trace.mean()records the mean temperature of a region andgfem.Trace.point()the temperature at a point, both absolute, in K.thermo_optic_shift(...).trace()androute_phase(...).trace(name)record the phase (per metre on a section, in rad along a route): their mode is solved once, before the run, and needs no rise.gfem.Trace.heat_out_per_length()records the heat that has left through the sink (“The heat that has left”).With no
initial_temperature, the run starts from the source-free temperature, so every rise starts at 0. A number starts the whole device at that uniform temperature, in K.
Fields at chosen times#
The run keeps the temperature field at the final time and at the times
named in keep_fields (True keeps every step):
print(np.round(np.asarray(run.kept_times) * 1e6, 6)) # us
halfway = run.rise(40e-6) # a Field, K
print(f"mean core rise at 40 us: {float(gfem.region_mean(halfway, 'core')):.3f} K")
[ 40. 160.]
mean core rise at 40 us: 11.818 K
run.temperature(time) gives the absolute temperature. Asking for a time
that was not kept raises, naming the kept ones. Each kept field holds every
node’s value, so keep only the times you need on a large mesh.
Rise time and time constant#
gfem.rise_time() is the 10–90 % time of a trace, and
gfem.time_constant() the time to \(1 - 1/e\) = 63.2 % of its swing.
Both normalise the trace between its first and last samples, so pass the
part of the trace that goes with one switch, and that switch’s time:
tau = gfem.time_constant(t[on], core[on], switch_times=(0.0,))
rise = gfem.rise_time(t[on], core[on], switch_times=(0.0,))
off = t >= t_off
tau_off = gfem.time_constant(t[off], core[off], switch_times=(t_off,))
print(f"time constant: {tau * 1e6:.2f} us on, {tau_off * 1e6:.2f} us off")
print(f"10-90 % rise time: {rise * 1e6:.2f} us, ratio {rise / tau:.2f}")
time constant: 8.56 us on, 8.56 us off
10-90 % rise time: 18.56 us, ratio 2.17
The model is linear, so the fall mirrors the rise.
A single exponential has rise time / time constant = \(\ln 9 = 2.20\). A ratio near it means one slow thermal mode dominates.
Both take plain arrays of times and values, from gfem or anywhere else.
The heat that has left#
gfem.Trace.heat_out_per_length() records the heat out of a
side: the heat that has left it since \(t = 0\), in J/m (J on a 3D mesh, with
gfem.Trace.heat_out()). It takes the sides of
gfem.heat_flow_per_length: surface names, volume regions or a
predicate on the element centroids. Its step difference over dt is the
mean heat flow over each step, in W/m, which tends to the steady
flow once the temperature has settled:
heat_out = np.asarray(run.traces["sink"]) # J/m since t = 0
dt = t[1] - t[0]
flow = np.diff(heat_out) / dt # W/m, the mean over each step
steady = gfem.solve(model, gfem.SteadyThermal(step.heat))
held = float(gfem.heat_flow_per_length(steady, "bottom", model=model))
put_in, out = 70.0 * t_off * 1e3, heat_out[-1] * 1e3 # mJ/m
print(f"heat in: {put_in:.4f} mJ/m, out by the end: {out:.4f} mJ/m")
print(f"mean flow over the last step on: {flow[on[1:]][-1]:.4f} W/m")
print(f"steady flow into the sink: {held:.4f} W/m")
heat in: 5.6000 mJ/m, out by the end: 5.5988 mJ/m
mean flow over the last step on: 69.9032 W/m
steady flow into the sink: 69.9978 W/m
The heat is read from the discrete heat balance, with the heat the elements store: the heat out of every surface plus the heat stored equals the heat the sources put in, at every time, whatever the time scheme.
At switch-off, nine time constants after the switch-on, the flow into the sink is 0.14 % short of the steady one: slower thermal modes than the core’s are still filling. By the end of the run the device has given back all but 0.02 % of its heat; the rest is still stored, or left through the top.
The trace is a cumulative heat, so
gfem.rise_time()andgfem.time_constant()have no meaning on it: takenp.difffirst, and measure the flow.
A trace that has not settled#
The normalisation needs the trace to end where it is going. When the last
samples still change, by more than 1 % of the swing extrapolated, the
settled trace test fails and both functions warn with
gfem.UnsettledTraceWarning. The first 15 µs of the step, under
two time constants, are not settled:
early = t <= 15e-6
with warnings.catch_warnings(record=True) as caught:
warnings.simplefilter("always")
gfem.time_constant(t[early], core[early], switch_times=(0.0,))
print([w.category.__name__ for w in caught])
['UnsettledTraceWarning']
Run longer, or switch later: about five time constants after the last switch settle a single-exponential response to 1 %.
The time scheme#
The default scheme, TR-BDF2, is second order and damps the jump at a
switch. SolverOptions(time_scheme="theta", theta=1.0) is backward Euler,
first order: use it to compare with a code that steps that way, at the same
time grid. theta=0.5 is Crank-Nicolson.
euler = gfem.solve(
model,
gfem.TransientThermal(
step.heat,
duration=80e-6,
steps=160,
traces={"core": gfem.Trace.mean("core")},
),
options=gfem.SolverOptions(time_scheme="theta", theta=1.0),
)
core_euler = np.asarray(euler.traces["core"])
t_euler = np.asarray(euler.time)
tau_euler = gfem.time_constant(t_euler, core_euler, switch_times=(0.0,))
print(f"time constant, backward Euler: {tau_euler * 1e6:.2f} us")
time constant, backward Euler: 8.86 us
Backward Euler lags by 3.5 % at 0.5 µs steps. It is first order, so halving the step roughly halves the lag.
Check your results#
Steps. Halve
duration / stepsand compare the time constant: with TR-BDF2 the change falls about four times per halving.The final value. Run long after a step on and compare the trace’s last value with a
gfem.SteadyThermalsolve of the same source.Linearity. Twice the power gives twice every rise, at every time.
Limits#
The time grid is uniform, set by
durationandsteps; there is no adaptive stepping. A heater switched on for a short time needs steps much shorter than that time.Heat sources switch between constant levels, at grid times. A ramp is a staircase of switches.
Materials are constant and linear, as in the steady solve.
A run holds one factorization, the traces and the kept fields in memory. A gradient through a long run also keeps the trajectory, or checkpoints it when it does not fit (Differentiate a heater’s phase).
Next#
Heat a device with a current and read its temperature: the steady temperature, boundaries and drives.
Find the phase a heater puts on a waveguide: phases on a section and along a route.
Differentiate a heater’s phase: the gradient of a trace or a time constant’s inputs.
A thermo-optic phase shifter: a TiN heater over a silicon waveguide: the step response of a phase shifter, against a published device.