Request several modes on one port surface#
Get one S-matrix with a row and a column for each guided mode at each end of
a polarization rotator, a mode converter or a taper.
S["out_TM0", "in_TE0"], for example, is the fraction of the TE0 wave
launched at the input that leaves as TM0. Several gfem.WavePorts on
one surface, one mode each, form a shared port surface: one
boundary that absorbs and launches each requested mode.
The example is a 500 × 220 nm silicon strip in oxide at 1.55 µm, which
carries a TE-like and a TM-like fundamental mode (TE0 and TM0). The gmsh
mesh has two leads of the strip ending on the exterior surfaces port1 and
port2, and a core and a cladding region. It also has an outer surface
outer and, between the leads, the device: a region design. Each lead is uniform near its port face, so the port mode problem of
the face describes the guided modes of the lead.
Set up the ports#
Put one wave port per mode on each port surface, each with its own name:
import gfem
f0 = 299792458.0 / 1.55e-6 # Hz
mesh = gfem.Mesh.from_gmsh("strip.msh", length_unit="um")
model = gfem.Model(
mesh,
materials={
"cladding": gfem.Material(eps_r=1.444**2),
"core": gfem.Material(eps_r=3.476**2),
"design": gfem.Material(eps_r=1.444**2),
},
boundaries=[gfem.Absorbing("outer", order=2)],
ports=[
gfem.WavePort("in_TE0", "port1", mode=1, pec_edges=("outer",)),
gfem.WavePort("in_TM0", "port1", mode=2, pec_edges=("outer",)),
gfem.WavePort("out_TE0", "port2", mode=1, pec_edges=("outer",)),
gfem.WavePort("out_TM0", "port2", mode=2, pec_edges=("outer",)),
],
)
result = gfem.solve(model, gfem.Driven(frequency=f0))
s = result.s
s["out_TE0", "in_TE0"] # TE0 transmitted as TE0
s["out_TM0", "in_TE0"] # TE0 converted to TM0
Every API keyed by port name works per mode: Driven(excite=...),
result.port_modes["in_TM0"], s.z_ref, Touchstone and xarray export, and
the saved job.
Each mode is its own port. S is made of each mode’s waves: modal amplitudes normalized to 1 W on a lossless line, or the mode’s pseudo-waves with a
voltage_path(gfem.conventions).s.y(),s.z()ands.renormalize()act on modal voltages and currents, one per mode, not on the conductors’ terminal ones.One surface, one cross-section. The wave ports of one surface must request different
modes and give the samepec_edges; agfem.LumpedPortor a boundary condition cannot share the surface with them.gfem.ModelraisesValueErrorotherwise.Per port.
offset,voltage_pathandpolaritybelong to each port. Each mode is de-embedded with its own propagation constant. Avoltage_pathfixes that mode’s sign (Re V > 0along the path) and gives itsz_ref. Without one, a mesh-dependent rule fixes the sign of the port’s row and column of S, and in 3D so does the model’s orientation in the global frame.|S|and every power are unaffected, but the phase of a cross-mode entry is then not comparable between meshes: give avoltage_pathto compare phases. Apolarityfixes a mode’s sign without defining a voltage, one arrow per port (TE0 and TM0 on one surface take different arrows): use it to compare phases, or in a circuit.modeis a rank, not a polarization. It is the mode’s rank at the lowest frequency of the solve, 1 being the most confined (the largest effective index). Check which rank is TM0 before naming a port after it:tm0 = gfem.solve(model, gfem.PortMode("in_TM0", f0)) tm0.n_eff # the TM-like strip mode has the lower index
or look at
tm0.e_field, which points mostly normal to the wafer for a TM-like mode. On a shared port surface,PortModeruns the surface’s joint sweep, so it gives the same mode the driven solve uses. For this strip TE0 is rank 1 and TM0 rank 2.Driven fields. A kept field (
Driven(keep_fields=...)) is the field for 1 W incident in one requested mode, with every other port terminated. The other modes of the excited port’s own surface are absorbed (matched) like those of the far end.
Differentiate a conversion#
A conversion entry differentiates like any other S entry. In a straight strip
whose stack is symmetric about its mid-plane, TE0 and TM0 do not couple, so
S["out_TM0", "in_TE0"] is zero; a device that breaks that symmetry converts
one into the other. Make the device a gfem.MaterialField on a region kept
off both port faces and maximize the conversion:
import jax
import jax.numpy as jnp
problem = gfem.Driven(frequency=f0)
def conversion_loss(eps):
"""1 - |S(out_TM0, in_TE0)|^2, for a permittivity per design element."""
m = model.with_material("design", gfem.MaterialField(eps_r=eps))
s = gfem.solve(m, problem).s
return 1 - jnp.abs(s["out_TM0", "in_TE0"]) ** 2
n = len(mesh.elements("design"))
value, grad = jax.value_and_grad(conversion_loss)(jnp.full(n, 1.444**2))
The cost rule of Differentiate S-parameters and driven fields applies per mode. With every port
excited (the default), a lossless port line needs no extra solve: each
port’s solution is its own adjoint. With Driven(excite=["in_TE0"]), reading
the out_TM0 row costs one adjoint solve per frequency. Adaptive sweeps
differentiate as for one mode per port
(Differentiate an adaptive frequency sweep).
Check your results#
Reciprocity.
Sshould equal its transpose to the solver’s tolerance.Power. For a lossless device with every propagating mode requested,
SᴴSshould be the identity: no power goes anywhere S does not show.Power through a plane.
gfem.power_flowthrough a plane in the output lead (see Measure fields after the solve) should equalΣ_k |S[out_k, in]|², the sum over the requested modes at that end.
How gfem itself is checked on wave ports and shared port surfaces: How gfem is checked.
Limits#
Unrequested modes are reflected, not converted. A propagating mode that no wave port on its surface requests is partly reflected at the port, by about \((\beta_j - \beta_0)/(\beta_j + \beta_0)\). Here \(\beta_j\) is its propagation constant and \(\beta_0\) that of the surface’s lowest-ranked requested mode. It is never converted into a requested mode there, so S misses the power the device sends into it. Request it to see where that power goes. A mode ranked below the highest requested one and left out (a lone
mode=2, or modes 1 and 3) warns withgfem.SkippedPortModeWarning. Modes above the highest requested rank never warn.Mirror half models. On a mirror half model the ranks count only the modes the symmetry plane admits, so a mode of the other parity is not a gap. A PMC or PEC plane through the strip’s mid-height admits only one of TE0 and TM0: requesting both needs the full stack.
Lossy port lines. S reads each mode by the biorthogonal projection, which separates the requested modes by reciprocity with or without loss in the cross-section, and matches a lossy port line to its own mode. Give every wave port of the device a
voltage_path, or none: on a lossy line the two kinds of waves differ, and S is symmetric only between ports of one kind.Degenerate, crossing and cut-off modes. The solve raises
gfem.PortModeError, naming the port and the surface, in three cases. A requested mode degenerate with another (TE10 and TE01 of a square guide) has no defined field: select one polarization with a symmetry plane through the guide’s axis (a mirror half model), or break the cross-section’s symmetry with aWavePort(pec_edges=...)wall. Two requested modes that follow the same mode through an unresolved crossing: narrow the band or break the symmetry. A requested mode below cutoff somewhere in the band: narrow the band. A lossy mode counts as below cutoff where its attenuation is at least its phase constant, \(\operatorname{Re} \beta \le |\operatorname{Im} \beta|\). A clean crossing is followed and warns withgfem.PortModeTrackingWarning.Eigenmodes.
gfem.Eigenmodetakes a shared port surface. Each wave port’s coupling Q comes from its own mode’s amplitude; the cross terms between the modes, zero on a lossless section, are dropped.Designs on a port face. A design with elements on the shared face changes every requested mode, and S between them follows; the modes stay separated by the biorthogonal projection, lossy or not (Differentiate port modes and designs at a port).
Next#
gfem.WavePort, gfem.PortMode, gfem.conventions,
Differentiate S-parameters and driven fields (S objectives, their cost and what raises),
Measure fields after the solve (power through a plane, probes, characteristic
impedance).